SINGLE PHASE ENCAPSULATED TRANSFORMERS
Specifications
Metal encapsulated enclosure, Protection index IP-55
Vacuum-pressure impregnation with thermosetting polyster resin
Temperature class insulating materials : B
Insulation class : F
Max. ambiebt temperature : 50 C
Electrical protection class : I
Insulation between PRI and SEC ( for V < 450V ) : 4.8KV
Frequency : 50/60Hz
Terminals : Bolt terminals ( M4, M6, M8... etc )
Powder coated wall mounted enclosure RAL 7032
Cast resin encapsulation
Impregnated Single Phase Transformers - IP-44
Specifications
Standard : According to EN-61558
Enclosed type, Degree of protection IP-44, IP-55 ( Other type of protection as per request )
Powder coated floor mounted type metal enclosure RAL 7032 & 7035
Winding : Enamelled copper wire Class F, B, H Galvanically isolated
Temperature class insulating materials : B
Insulation class : F
Max. ambient temperature : 25 C to 50 C
Electrical protection class : I
Max. temperature rise : 95 C
Insulation between PRI and SEC ( for V < 450V ) : 4.8KV
Frequency : 50Hz, 60Hz, 50/60Hz
Fixing system : Through angles DIN 41307
Terminals : Screw type connector, screw type terminal block and terminals are protected against corrosion
Impregnated Single Phase Transformers - IP-00
Specifications
Standard : According to EN-61558
Open construction, Degree of protection IP-00
Winding : Enamelled copper wire Class F, B, H Galvanically isolated
Temperature class insulating materials : B
Insulation class : F
Max. ambient temperature : 25 C to 50 C
Electrical protection class : I
Max. temperature rise : 95 C
Insulation between PRI and SEC ( for V < 450V ) : 4.8KV
Frequency : 50Hz, 60Hz, 50/60Hz
Fixing system : Through angles DIN 41307
Type : Dry type, Vaccum impregnation
Terminals : Screw type connector, screw type terminal block and terminals are protected against corrosion
Impregnated Three Phase Transformers - IP-44
Specifications
Standard : According to EN-61558
Enclosed type, Degree of protection IP-44, 55, 23 etc....
Powder coated floor mounted metal enclosure RAL 7032 & 7035
Winding : Enamelled copper wire Class F, B, H Galvanically isolated
Temperature class insulating materials : B
Insulation class : F
Max. ambient temperature : 25 C to 50 C
Electrical protection class : I
Max. temperature rise : 95 C
Insulation between PRI and SEC ( for V < 450V ) : 4.8KV
Frequency : 50Hz, 60Hz, 50/60Hz
Fixing system : Through angles DIN 41307
Terminals : Screw type terminal block for Type 1, Bolt terminal for Type 2 (M8, M10 etc.... ) and terminals are protected against corrosion
Impregnated Three Phase Transformers - IP-00
Specifications
Standard : According to EN-61558
Open construction, Degree of protection IP-00
Winding : Enamelled copper wire Class F, B, H Galvanically isolated
Temperature class insulating materials : B
Insulation class : F
Max. ambient temperature : 25 C to 50 C
Electrical protection class : I
Max. temperature rise : 95 C
Insulation between PRI and SEC ( for V < 450V ) : 4.8KV
Frequency : 50Hz, 60Hz, 50/60Hz
Fixing system : Through angles DIN 41307
Terminals : Screw type terminal block for Type 1, Bolt terminal for Type 2 (M8, M10 etc.... ) and terminals are protected against corrosion